Valves Emergency Shut-off JIS
874501 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-25-PC
IMPA:874501
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874502 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-40-PC
IMPA:874502
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874503 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-50-PC
IMPA:874503
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874504 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-65-PC
IMPA:874504
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874505 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-80-PC
IMPA:874505
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874506 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-100-PC
IMPA:874506
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874507 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-125-PC
IMPA:874507
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874508 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-150-PC
IMPA:874508
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874509 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-200-PC
IMPA:874509
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874510 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE PNEUMATIC ESG-250-PC
IMPA:874510
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874511 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-25-WR
IMPA:874511
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874512 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-40-WR
IMPA:874512
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874513 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-50-WR
IMPA:874513
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874514 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-65-WR
IMPA:874514
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874515 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-80-WR
IMPA:874515
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874516 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-100-WR
IMPA:874516
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874517 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-125-WR
IMPA:874517
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874518 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-150-WR
IMPA:874518
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874519 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-200-WR
IMPA:874519
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874520 VALVE SHUT-OFF EMERGENCY JIS5K, GLOBE WIRE PULL ESG-250-WR
IMPA:874520
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874521 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-25-PC
IMPA:874521
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874522 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-40-PC
IMPA:874522
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874523 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-50-PC
IMPA:874523
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874524 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-65-PC
IMPA:874524
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874525 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-80-PC
IMPA:874525
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874526 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-100-PC
IMPA:874526
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874527 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-125-PC
IMPA:874527
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874528 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-150-PC
IMPA:874528
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874529 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-200-PC
IMPA:874529
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874530 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE PNEUMATIC ESA-250-PC
IMPA:874530
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Pneumatic Control Type
874531 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-25-WR
IMPA:874531
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874532 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-40-WR
IMPA:874532
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874533 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-50-WR
IMPA:874533
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874534 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-65-WR
IMPA:874534
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874535 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-80-WR
IMPA:874535
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874536 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-100-WR
IMPA:874536
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874537 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-125-WR
IMPA:874537
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874538 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-150-WR
IMPA:874538
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874539 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-200-WR
IMPA:874539
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874540 VALVE SHUT-OFF EMERGENCY JIS5K, ANGLE WIRE PULL ESA-250-WR
IMPA:874540
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874541 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-25-PC
IMPA:874541
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874542 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-40-PC
IMPA:874542
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874543 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-50-PC
IMPA:874543
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874544 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-65-PC
IMPA:874544
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874545 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-80-PC
IMPA:874545
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874546 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-100-PC
IMPA:874546
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874547 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-125-PC
IMPA:874547
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874548 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-150-PC
IMPA:874548
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874549 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-200-PC
IMPA:874549
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874550 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K PNEUMATIC ESG-250-PC
IMPA:874550
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874551 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K WIRE PULL ESG-25-WR
IMPA:874551
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874552 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K WIRE PULL ESG-40-WR
IMPA:874552
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874553 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K WIRE PULL ESG-50-WR
IMPA:874553
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874554 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K WIRE PULL ESG-65-WR
IMPA:874554
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874555 VALVE SHUT-OFF EMERGENCY GLOBE, JIS 10K WIRE PULL ESG-80-WR
IMPA:874555
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874556 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-25-PC
IMPA:874556
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874557 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-40-PC
IMPA:874557
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874558 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-50-PC
IMPA:874558
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874559 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-65-PC
IMPA:874559
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874560 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-80-PC
IMPA:874560
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874561 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-100-PC
IMPA:874561
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874562 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K PNEUMATIC ESA-125-PC
IMPA:874562
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874563 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K WIRE PULL ESA-25-WR
IMPA:874563
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874564 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K WIRE PULL ESA-40-WR
IMPA:874564
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874565 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K WIRE PULL ESA-50-WR
IMPA:874565
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874566 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K WIRE PULL ESA-65-WR
IMPA:874566
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
874567 VALVE SHUT-OFF EMERGENCY ANGLE, JIS 10K WIRE PULL ESA-80-WR
IMPA:874567
MTML UOM:PCE
For marine use on tanks containing oil fuel, lub. oil and other flammable oil which are required to have valves closed from safe positions outside the space concerned. Made of cast iron and available two types of style : Globe type and Angle type, and also available two types of operation: Pneumatic Control type and Wire Rope Pull type as shown below, for flange specification, JIS type.
Shut-off Operation; The Pneumatic Control Type: Only open the compressed air supply valve connected from air reservoir. Air reservoir should be kept certain pressure between 0.39 MPa and 0.89 MPa. The Wire Rope Pull Type; Only pull the lever connected with wire rope. For manual shut, these valves are able to close with handle wheel by rotating in clockwise direction.
Reset after Shut-off: 1. Rotate clockwise until a head of piston is set in the grooving on spindle, and then rotate counterclockwise the handle to set valve in full open condition. 2. For small size valves (Max. 3") under the low level of liquid in tank (max. 5 mtr height), the valves can be reset with one touch by lifting the handle upward. * Regarding Pneumatic Control Type, 1 or 2 should be applied after air supply valve is closed. * Shut-off Operation: Wire Rope Pull Type
© 2025 ShipServ Limited